Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
CorSalud ; 12(3): 292-300, jul.-set. 2020. tab
Article in Spanish | LILACS | ID: biblio-1154034

ABSTRACT

RESUMEN Introducción: En los cambios de la geometría ventricular en hipertensos influyen el control de la presión arterial durante las 24 horas del día, así como su descenso adecuado en el período nocturno. Objetivo: Describir los patrones geométricos del ventrículo izquierdo en pacientes con y sin hipertensión arterial nocturna. Método: Se realizó monitoreo ambulatorio de la presión arterial (MAPA) y ecocardiograma a 54 pacientes con hipertensión arterial del 2016 al 2017. Se calcularon las variables de MAPA: promedio y cargas de presión diurno, nocturno y 24 horas, y el patrón circadiano. En el ecocardiograma se midieron los diámetros, el tabique interventricular y la pared posterior del ventrículo izquierdo, se calculó su masa e índice de masa, y se determinó su patrón geométrico y de función diastólica. Resultados: La edad promedio fue 55,4±14,1 años y predominaron el sexo femenino (57,4%) y el color de la piel blanco (59,3%). La hipertensión arterial al despertar y nocturna se halló en el 38,9% y 51,9%, respectivamente, y el fenómeno dipper alterado en 68,5% de los pacientes, asociado significativamente al incremento de la presión arterial nocturna (p=0,001). El tabique interventricular fue significativamente mayor en pacientes con hipertensión arterial nocturna en comparación con el grupo que no la presentaba (11,1±2,2 vs. 9,6±1,4 mm; p=0,006). Predominó la geometría alterada (53,7%) a expensas de mayor remodelado concéntrico (40,7%), sin asociación con la hipertensión arterial nocturna. Conclusiones: Los patrones geométricos del ventrículo izquierdo se comportaron de forma similar en pacientes con y sin hipertensión arterial nocturna.


ABSTRACT Introduction: Changes in ventricular geometry in hypertensive patients are influenced by 24-hour control of blood pressure, as well as its adequate decrease during nighttime. Objective: To describe the left ventricle geometric patterns in patients with or without nocturnal hypertension. Method: An ambulatory blood pressure monitoring (ABPM) and an echocardiogram were performed on 54 patients with high blood pressure, from 2016 to 2017. The following ABPM variables were calculated: average and pressure loads of daytime, nighttime, and 24-hour, as well as circadian pattern. In the echocardiogram, the diameters, the interventricular septum and the left ventricular posterior wall were measured; its mass and mass index were calculated, as well as determined its geometric and diastolic function patterns. Results: The average age was 57.4%±14.1 years old. Females (57.4%) and white skin color (59.3%) predominated. Waking and nocturnal hypertension were found in 38.9% and 51.9% respectively, and the altered dipper phenomenon was found in 68.5% of the patients, significantly associated with increased nocturnal blood pressure (p=0.001). The interventricular septum was considerably higher in patients with nocturnal hypertension when compared to the group without it (11.1±2.2 vs. 9.6±1.4 mm; p=0.006). Altered geometry predominated (53.7%) at the expense of higher concentric remodeling (40.7%), without any association with nocturnal hypertension. Conclusions: Left ventricle geometric patterns behaved similarly in patients with and without nocturnal hypertension.


Subject(s)
Echocardiography , Blood Pressure Monitoring, Ambulatory , Pulmonary Arterial Hypertension
SELECTION OF CITATIONS
SEARCH DETAIL